EN  

DTSD1352-4S Multi-circuit Energy Meter for Tower Base Stations

DTSD1352-4S


● Mearsure up to 4 circuit 3 phase

● Mearsure all electric parameters
● Split core open loop CTs

● LCD Display



Description

General



DTSD1352-4S series DIN-rail type multi-circuit power meter is mainly used for the full electric parametermeasurement of multiple circuits, and can be connected to the current input of 4 three-phase circuits or 12single-phase circuits at the same time. It can measure parameters such as voltage and current, power, power factor,phase angle, unbalance, and harmonics.


Function




Accuracy

Active power: Class 1
Reactive power: Class 2


Frequency

Range: 45 - 65Hz


Pulse output

Output method:optocoupler pulse with open collector



Power Consumption

≤10VA





Dimension (L*W*H)

Panel size (L×W×H): 87.8*72*71.5 mm

Installation: Din 35mm


Current
:Overload: 1.2 times rated value (continuous);


Parameter


Auxiliary power
AC/DC 85~265V; Consumption≤10VA;


Input



Frequency
45~65Hz;

Voltage

AC 3×220V/380V; Overload: 1.2 times of rated value (continuous);

2 times of rated value / 1s; Power consumption: ≤ 0.5VA;each channel)

Current

Rated value: Secondary input rated current:50mA;Overload: 1.2 times rated value (continuous); 10 times rated value/1 second;power consumption: ≤ 0.5VA(each channel);

Measurement accuracy

Frequency: 0.05Hz, voltage and current: 0.5 class, active energy: 1 class, reactive energy: 2 class; 2nd to 31st harmonic accuracy: ±1%;



Features

Pulse output
Output method: optocoupler pulse with open collector,the pulse constant defaults to 400imp/kWh (and active open input can only be either-or.);
Communication
RS485 interface, Modbus-RTU protocol; baud rate 1200~38400;
Switching Input
2-way or 4-way passive dry contact input, built-in power supply;
2-way active wet node input (AC220V), identify the oil generator and mainsaccess (and pulse output can only be either-or.);

Switching Output

Output method: relay normally open contact output;
Contact rating: AC 250V/3A DC 30V/3A;




Dimension



Meter (L×W×H): 87.8*72*71.5mm

35mm Din rail installation; Tolerance: ±1mm


Type Ratio Line Length Accuracy Installation Method
AKH-0.66/W-9NY 50A/20mA 50A/20mA (1+0.2)m Class 0.2 Closed type, crystal head interface
AKH-0.66/K-Φ10N 50A/20mA 50A/20mA (1+0.2)m Class 0.5 Open type, crystal head interface
AKH-0.66/W-12NY 100A/50mA 100A/50mA (1+0.2)mClass 0.2 Closed type, crystal head interface
AKH-0.66/K-Φ16N 100A/50mA 100A/50mA (1+0.2)m Class 0.5 Open type, crystal head interface
AKH-0.66/W-20Y 200A/50mA 200A/50mA (1+0.5)mClass 0.2 Closed type, crystal head interface
AKH-0.66/K-Φ24N 200A/50mA 200A/50mA (1+0.5)m Class 0.5 Open type, crystal head interface
AKH-0.66/W-30NY 250A/50mA 250A/50mA (1+0.5)m Class 0.2 Closed type, crystal head interface
AKH-0.66/K-Φ24N 250A/50mA 250A/50mA (1+0.5)mClass 0.5 Open type, crystal head interface
AKH-0.66-TD-Φ60-NY 300-1000A/50mA (1+0.5)mClass 0.2 Closed type, crystal head interface
AKH-0.66/K-Φ36N 400A/50mA 400A/50mA (1+0.5)m Class 0.5 Open type, crystal head interface
AKH-0.66/K-Φ36N 600A/50mA 600A/50mA (1+0.5)m Class 0.5 Open type, crystal head interface







Installation



Wiring





Network


Package



MINIMUM PACKAGE







MINIMUM PACKAGE


Package Dimension(1 PC)

170*150*130mm

Package Weight(1 PC)

0.245Kg


WHOLE BOX PACKAGE


Package Dimension(36 PCS)

540*530*480mm

Package Weight(36 PCS)

10.5kG


PRODUCT HS CODE


9028301400

ATTENTION !

The above packing and weight data are only refer to model ADW210.

For other models or optional functions, please contact the salesman for details, thank you for your cooperation!







Inquiry Now

Would you like to get information about Acrel? We appreciate your interest and would be happy to advise you.Simply give us some information so we can get in touch with you

GET YOUR FREE QUOTE

We will contact you within 24 hours.

X